Nd Yag Laser Q-Switched Tattoo Removal Beauty Salon Equipment 532Nm 1064Nm 1320Nm Probes

Cryolipolysis Slimming Machine

  • $960.00
    Unit price per 
  • Save $192.00
Shipping calculated at checkout.

Only 1000 left!

The Latest Portable Nd Yag Laser Q-Switched Tattoo Removal Machine Beauty

Salon Equipment 532Nm 1064Nm 1320Nm Probes Laser Machine

Forinner melanin:Nevus,coffee spot,age spot,skin pigmentation,Insdation spot,ToenailFungus removal.
For out source melanin:Tattoo on body,eye lineand eyebrow line.
Hair removal&Skin rejuvenation.

 

Application

The system gem-adjusting Q switch can effectively curethe mixed pigments by pigment precipitation of extraneous source withpathological pigment change of endogenous source, inclusive of erroneous darkeyebrowembroidery, lip-embroidery, lip-soak, eye line-embroidery, lip-line,tattoo (inclusive of tattoo by extraneous wounds),pigment precipitationbysensitive source, freckle on female\`s face (male\`s), coffee spot, old agespot, black mole, and birthmark in black, blue, purple, brown, red and etc.Treatment course for different illness case as follows:

Treatmentfor tattoo in eyebrow

Customer could not open eyes during treatment, operator should adjust energyaccording to depth of tattoo color, hold the handle and move it to treatmentarea slowly to make customer feel acceptable in mentally. Right now, the speedof flash could be set 3HZ, keep head of the handle a two-finger distance totreatment area, start treatment from head of eyebrow to end of eyebrow. It isneeded to treat again in 5-10 minutes if the color of tattoo re-appear.

 

Remove lip line

The speed of flashes could be set 5Hz,keep a 3/4 finger distance between headof handle and treatment area. It is better to remove black, coffee, deep, redand brown lip line with 1064nm head at first time and then, treat again with 532 nm

head.
Notice: All tattoos in lip should be treated in 6 months after making. ORremoval treatment will fail. It should have 45-60 days interval to continuenext treatment until remove all.

Remove eye line

The speed of flashes could be set 4-5HZ,adjust the energy of light to minimumenergy, keep a one-finger distance

between head of handle and treatment area.Operator should strictly protect customers` eyes with panel for eyelid

or pledget (panel for eyelid)of 25px depth.
Treatment should be started from down eye line, customer should deeply closeeyes and keep eyeball up-sight inside.

Operator should press the pledget (panelfor eyelid) with forefinger and push up eyelid, peel down eyelid with middlefinger to bare the eye line, treat it with flashes of 4-5Hz. Then, treat up eyeline.

Also customer should close eyes and keep eyeball down-sight inside.Operator should press the pledget (panel for eyelid) with middle finger andpush eyelid down, push eyelid up with forefinger to bare the eye line, treat itwith flashes of 4-5Hz.

Remove tattoo

The speed of flashes could be set 3Hz/5Hz.It is better to use high energy fortreatment until treatment area seeps a little

blood. It should have 45-90 daysinterval to continue next treatment until remove all.

Remove spot and nevus

The speed of flashes could be set 3Hz/5Hz.Keep 3-4 fingers distance betweenhead of handle and treatment area.

It is better to use high energy fortreatment until treatment area seeps a little blood. It is advised to use 1064nm head for normal spot and nevus treatment, but for deep color spot and nevus,it is better to use 532nm head for treatment. It

should have a 15-30daysinterval to continue next treatment until remove all.

Remove birthmark

The speed of flashes could be set 3Hz/5Hz.It is better to use high energy fortreatment until treatment area seeps a little blood. It is advised to use1064nm head for birthmark treatment, but for red and deep color birthmark, itis better to use

532nm head for treatment. It should have 45-90 days intervalto continue

product information

Certification:CE  

Type of laser: Solid-state Q-switch Nd:YAGlaser

Wavelength: 1064nm, 532nm ,1320NM

Output Energy: 2000mJ

Pulse duration: 8-10ns

Frequency: 1-10Hz

Power supply: AC220V 50Hz

Power:800W

Size:380mm×300mm×320mm

Weight: 19kg

Warranty:2 year  

Machine advantages

Touch screen Control
Sapphire cooling system ensures constantly working.
800W power and 1000mj energy.
Xenon lamp imported from Germany.
Portable and aseismatic,convenient for transportation.


FAQ

 

1. Do you have any warranty?Hair Removal

Yes, we have. One years warranty on host machine is given. Three months free replacement warranty for handles,

treatment heads, and parts

2. How is your after-sale service?Hair Removal

We have a professional technology supporting team for your timely services. You can get the help you need in time

by telephone, webcam, online chat (Google talk, Facebook, Skype). Please contact us once the machine has any

problem. Best service will be offered.

3. What certification do you have?Hair Removal

All of our machines have the CE certification which ensures the quality and safety. Our machines are under strict

quality management to ensure good quality. Because we fully understand that it will be a great trouble if machine

have any problem during working at oversea.

4. Will you teach how to use the machine?Hair Removal

Yes, we can provide a complete user manual and usage video for instruction and application. And 24/7 online

consultant service ensure you whatever problem and whenever you meet, you can solve easily. It is easy to operate

by anyone with the instructions.

5. How about the shipment?Hair Removal

The machine will be shipped within 2-3 days after the receipt of your payment.
6. Why should you choose us?Hair Removal
Powerful factory, giving the competitive price and best technology support
10-years` experience in producing beauty machine, strong R&D
1 years-warranty and 7x24 online after-sale service
CE Certification, the key for you to legally use and sell the machine
Diversity of customized service, strong OEM & ODMcapability available